| Detailed Product Description |
 |
500mA 500mA Medical Diagnostic X-ray Unit F99-ICT 500mA Microprocessor Controlled Medical Diagnostic X-ray Unit Automatic and manual control programs:
Programmable radiographic functions, provides 90 memory programs for radiography. The parameters can also be selected manually.
X-ray tube protection: X-ray tube heat capacity and load capacity are managed and protected by computer programs, to allow maximum utilization of the tube capacity and radiographic parameters.
Anatomical exposure selection: Exposure parameters can be set based on patient size and exposure position. The parameters can also be corrected and stored.
Safety function: The error self-diagnosis function can determine problems quickly and accurately. It can execute protection automatically and display error code.
Technical Specifications:
Power supply |
Voltage: 380V AC single phase
|
|
Capacity: ≥50kVA
|
|
Frequency: 50Hz
|
|
Inner resistance: 0.3Ω
|
|
Fluoroscopy
|
0.5~5mA 40~110kV Continually adjustment
|
|
Radiography
|
Tube voltage: 44~125kV adjustable by 44 steps
|
|
Tube current: 30~500mA adjustable by steps
|
|
Exposure time: 0.02~5s adjustable by 23 steps
|
|
Diagnostic table
|
Tilting range of table: +90°~0°~-15°
|
|
Spot film device: two division, four division radiography
|
|
X-ray tube stand
|
Linear and tilting radiography
|
|
Radiographic table
|
Tabletop movement: longitudinal / transverse
|
|
Lock mode electromagnetic lock
|
|
Bucky (oscillating type) Density N40
|
|
Focal Distance f0100
|
|
Ratio r8
|
|
X-ray tube assembly
|
XD51-20.40/125
|
|
XD52-30.50/125
|
|
Tomographic attachment
|
optional
|
|
Vertical bucky stand:
|
optional
|
1 Technique selection 2 Anatomical exposure selection 3 Bucky radiography and IBS 4 Error code display 5 Power on/off
Standard Configuration:
●500mA microprocessor controlled ●R/F control console ●Diagnostic table ZC15X-2 ●Radiographic table SC3-2 ●HV cable ●X-ray tube assembly ●X-ray tube stand ZZ-3 Options: ●TV system ●Remote controlled console
F99-IBT 500mA Medical Diagnostic X-ray Unit Configuration: H.T. Generator FS302-1 Diagnostic table ZC15X-2 X-ray tube assembly stand ZZ-3 X-ray tube assembly XD51-20.40/125 -T1D X-ray tube assembly XD52-30.50/125 -T2A H.T. cable DL6312 -1 H.T. cable DL6308 -1 Collimator XS2-1 Collimator XS1-1 Radiographic table SC3-2 Optional Simply remote-controlled unit TV system and spring counterpoise unit Vertical bucky stand
Tomographic attachment
Features:
- Two-table, two-tube
- Single-phase, full wave, high voltage rectification
- Protective devices for X-ray tube capacity, anode-starting and exposure timing
- SCR exposure switch
- Inner-balanced diagnostic table, motor driven table tilting and tabletop moving at head end electrically
- Spot film device with high density stationary grid and electromagnetic locks
- The tabletop of radiographic table can be moved inlongitudinal and transverse direction with electromagnetic locks. The oscillating bucky is mounted under table
- Ceiling-floor rail type tube stand, telescopic rotating tube arm, electromagnetic locks and double-cable safety device
- Motor-driven multi-leaf collimator and manual multi-leaf collimator with light beam indicator
- Interface for TV system and vertical bucky stand
- Motor-driven linear tomographic attachment can be selected, layer height adjusted manually
|
Item
|
Contents
|
|
Fluoroscopy
|
0.5 ~5mA, 45~110 kV adjustable continuously
|
|
Radiography
|
Radiography
|
50~125 kV adjustable continuously
|
|
Tube current
|
30~500 mA adjustable by 8 steps
|
|
Exposure time
|
0.02~5s adjustable by 23 step
|
|
Diagnostic table
|
Table tilting
|
+90°~ 0°~ - 15°motor-driven
|
|
Tabletop moving
|
500mm at head end
|
|
Spot film device
|
Movable range
|
Longitudinal: 720 mm
|
|
Transverse: ±125 mm
|
|
Compressing: 300 mm
|
|
Lock mode
|
Electro-magnetic lock
|
|
Bucky
|
Density: N40
|
|
Focus: f070
|
|
Ratio: r8
|
|
Film size
|
203×254mm (8"×10")
   
|
254×305mm (10"×12")

|
|
280×356mm (11"×14")

|
356×356mm (14"×14")
|
|
Collimator
|
Multi-leaf motor-driven
|
|
Tube stand
|
Adjustable range between ceiling and floor: 2650~3200mm
|
|
Sliding in longitudinal (along ceiling and floor rail): 2000mm
|
|
Moving movement (along rotation arm): 240mm (from focus to center of stand)
|
|
Vertical movement (along stand): 410~1800mm (from focus to the ground)
|
|
Radiographic table
|
Moving range of tabletop: Longitudinal: ±600 mm Transverse:±100 mm
|
|
Lock mode
|
Electromagnetic lock
|
|
Bucky (oscillating type)
|
Density: N40
|
|
Focus: f0100
|
|
Ratio: r8
|
|
Tabletop-film distance
|
78mm
|
|
X-ray tube assembly
|
Model
|
XD51-20,40/125(Ⅰ.PC)
|
XD52-30,50/125(Ⅱ.PC)
|
|
Focus
|
1×1/ 2×2mm
|
1×1/ 2×2mm
|
|
Speed
|
2800r/ min
|
2800r/ min
|
|
Power supply
|
Voltage
|
Single phase 380V AC
|
|
Capacity
|
≥30kVA
|
|
Frequency
|
50Hz
|
|
Inner resistance
|
0.3Ω
|
|
Item (Optional)
|
Contents
|
|
Tomographic attachment
|
Exposure angle: 10°, 30°, 50° 3 steps
|
|
Layer height: 0~220mm motor-driven
|
|
Vertical bucky stand
|
Height adjustable
|
|
Bucky tiltable
|
|